A SMALL EXPERIMENT / Spectroscopy
Light through a solution.
Change concentration and path length to see how absorbance and transmitted light are related.
Follow the light.
Beam opacity represents relative transmitted intensity, not the solution’s actual color. The calibration line uses the current path length.
- Absorbance, A
- —
- Light transmitted
- —
- Light absorbed
- —
What changes
Absorbance is linear in concentration; transmission is exponential.
The model, explained.
We hold the molar absorption coefficient ε at an illustrative 10,000 L mol⁻¹ cm⁻¹ at one fixed wavelength. ℓ is path length in cm, and c is concentration in mol/L. The slider uses µM, converted to mol/L before calculation. Absorbance has no units.
This assumes a homogeneous, dilute solution with unchanged chemical speciation and monochromatic light. Reflection, scattering, stray light, and detector limits are excluded, so light absorbed is 100% minus light transmitted. The graph is an ideal calibration, not experimental data.
Read about transmission spectroscopy from the Coblentz Society